Reports configuration

Reports configuration

To define reports' configuration one should:

  • From menu Tools choose Report ...

  • use the F10 key
The Reports dialog opens – see fig.15.1.

Figure 15.1: Reports' definition window
Image l19

The Title field serves for defining the name of whole set of reports.

It is possible to configure of 10 independent reports or to change recent definitions. To enter particular report's definitions one has to double-click on the report's number. Next dialog window opens (see fig. 15.2) where reports' details are declared.

Figure 15.2: Report's criteria definition dialog
Image l20

Now it is possible to define:

  1. Report's name in Name edit box
  2. Reports criteria:

    1. by selecting the first binary signal from signals list for Fist signal, and signal's level by means of Active/Inactive radio button. If first binary signal is not concerned option None should be selected (first position on the list).
    2. by selecting the second binary signal from signals list for Second signal, and signal's level by means of Active/Inactive radio button. If second binary signal is not concerned option None should be selected (first position on the list).
    3. By selecting first analog signal from upper Analog signal list and its value condition by Less than/Equal/Greater than radio button and defining its threshold value in the edit box.
    4. Next define the signal's value to compare with. If the condition applies to the signal's absolute value theAbs. Val field should be checked.
    5. If analog signal is not concerned option None should be selected (first position on the list).
    6. By selecting second analog signal from lower Analog signal list and its value condition by Less than/Equal/Greater than radio button and defining its threshold value in the edit box. If second analog signal is not concerned option None should be selected (first position on the list).
    7. Next define the signal's value to compare with.

      1. If the condition applies to the signal's absolute value theAbs. Val field should be checked.
      2. If analog signal is not concerned option None should be selected (first position on the list).
    8. In the Duration time edit box it is possible to define the minimal duration time of above condition coincidence.
The reporting criteria is fullfiling of four first above conditions (logical AND of a,b,c,d) in a time not shorted than defined in point e). TheOK button serves for confirming the report's criteria and for returning to the Reports dialog. After returning one can define successive reports (up to 10) or start reporting. In order to save reports' definitions one should push Save pushbutton in Reports dialog.

For each report it is possible to declare if following information will be enclosed within the report:

B-E
– the beginning and ending time
Time
– event's duration time
Quant.
– events' quantity
Total
– total time
In order to save above settings Save pushbutton should be used.

generated on shrek in 0.008 seconds